1234567891011121314151617 |
- # you can disable an alarm notification by setting the 'to' line to: silent
- alarm: active_processes
- on: system.active_processes
- class: Workload
- type: System
- component: Processes
- hosts: *
- calc: $active * 100 / $pidmax
- units: %
- every: 5s
- warn: $this > (($status >= $WARNING) ? (85) : (90))
- crit: $this > (($status == $CRITICAL) ? (90) : (95))
- delay: down 5m multiplier 1.5 max 1h
- summary: System PIDs utilization
- info: System process IDs (PID) space utilization
- to: sysadmin
|