12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576 |
- ## Adapters (controllers)
- template: megacli_adapter_state
- on: megacli.adapter_degraded
- class: Errors
- type: System
- component: RAID
- lookup: max -10s foreach *
- units: boolean
- every: 10s
- crit: $this > 0
- delay: down 5m multiplier 2 max 10m
- summary: MegaCLI adapter state
- info: Adapter is in the degraded state (0: false, 1: true)
- to: sysadmin
- ## Physical Disks
- template: megacli_pd_predictive_failures
- on: megacli.pd_predictive_failure
- class: Errors
- type: System
- component: RAID
- lookup: sum -10s foreach *
- units: predictive failures
- every: 10s
- warn: $this > 0
- delay: up 1m down 5m multiplier 2 max 10m
- summary: MegaCLI physical drive predictive failures
- info: Number of physical drive predictive failures
- to: sysadmin
- template: megacli_pd_media_errors
- on: megacli.pd_media_error
- class: Errors
- type: System
- component: RAID
- lookup: sum -10s foreach *
- units: media errors
- every: 10s
- warn: $this > 0
- delay: up 1m down 5m multiplier 2 max 10m
- summary: MegaCLI physical drive errors
- info: Number of physical drive media errors
- to: sysadmin
- ## Battery Backup Units (BBU)
- template: megacli_bbu_relative_charge
- on: megacli.bbu_relative_charge
- class: Workload
- type: System
- component: RAID
- lookup: average -10s
- units: percent
- every: 10s
- warn: $this <= (($status >= $WARNING) ? (85) : (80))
- crit: $this <= (($status == $CRITICAL) ? (50) : (40))
- summary: MegaCLI BBU charge state
- info: Average battery backup unit (BBU) relative state of charge over the last 10 seconds
- to: sysadmin
- template: megacli_bbu_cycle_count
- on: megacli.bbu_cycle_count
- class: Workload
- type: System
- component: RAID
- lookup: average -10s
- units: cycles
- every: 10s
- warn: $this >= 100
- crit: $this >= 500
- summary: MegaCLI BBU cycles count
- info: Average battery backup unit (BBU) charge cycles count over the last 10 seconds
- to: sysadmin
|