The redis_master_link_down
alert is triggered when there is a disconnection between a Redis master and its slave for more than 10 seconds. This alert indicates a potential problem with the replication process and can impact the data consistency across multiple instances.
Examine the Redis logs for any errors or issues regarding the disconnection between the master and slave instances. By default, Redis log files are located at /var/log/redis/redis.log
. Look for messages related to replication, network errors or timeouts.
grep -i "replication" /var/log/redis/redis.log
grep -i "timeout" /var/log/redis/redis.log
Connect to the Redis master using the redis-cli
tool, and execute the INFO
command to get the detailed information about the master instance:
redis-cli
INFO REPLICATION
Also, check the replication status on the slave instance. If you have access to the IP address and port of the slave, connect to it and run the same INFO
command.
Test the network connectivity using ping
and telnet
or nc
commands, ensuring that the connection between the master and slave instances is stable and there are no issues with firewalls or network policies.
ping <slave_ip_address>
telnet <slave_ip_address> <redis_port>
If Redis instances are experiencing issues or are unable to reconnect, consider restarting them. Be cautious as restarting instances might result in data loss or consistency issues.
sudo systemctl restart redis
After addressing the potential issues, keep an eye on the Redis instances to ensure that the problem doesn't reoccur.