Browse Source

CURA-4634 Remove standby temperature from quality profiles

Diego Prado Gesto 7 years ago
parent
commit
14e99cef17

+ 1 - 2
resources/quality/ultimaker3/um3_aa0.4_BAM_Draft_Print.inst.cfg

@@ -15,8 +15,7 @@ cool_fan_full_at_height = =layer_height_0 + 2 * layer_height
 cool_fan_speed_max = =cool_fan_speed
 machine_nozzle_cool_down_speed = 0.75
 machine_nozzle_heat_up_speed = 1.6
-material_print_temperature = =230
-material_standby_temperature = 100
+material_print_temperature = =default_material_print_temperature + 5
 # prime_tower_enable: see CURA-4248
 prime_tower_enable = =min(extruderValues('material_surface_energy')) < 100
 skin_overlap = 20

+ 0 - 2
resources/quality/ultimaker3/um3_aa0.4_BAM_Fast_Print.inst.cfg

@@ -11,12 +11,10 @@ weight = -1
 setting_version = 4
 
 [values]
-default_material_print_temperature = 225
 cool_fan_full_at_height = =layer_height_0 + 2 * layer_height
 cool_fan_speed_max = =cool_fan_speed
 machine_nozzle_cool_down_speed = 0.75
 machine_nozzle_heat_up_speed = 1.6
-material_standby_temperature = 100
 # prime_tower_enable: see CURA-4248
 prime_tower_enable = =min(extruderValues('material_surface_energy')) < 100
 speed_print = 80